Directional characteristics | Cardioid |
Principle of operation | Pressure gradient |
Cartridge type | 19 mm (0.75 in) pre-polarized condenser |
Frequency range, ± 2 dB | On-axis: 40 Hz - 20 kHz |
Sensitivity, nominal, ±2 dB | 12 mV/Pa; -38 dB re 1 V/Pa |
Equivalent noise level A-weighted | Typ. 19 dB(A) re. 20 μPa (max. 20 dB(A)) |
Equiv. noise level ITU-R BS.468-4 | Typ. 25 dB |
S/N ratio, re. 1 kHz at 1 Pa (94dB SPL) | 75 dB(A) |
Total harmonic distortion (THD) | <0.5% up to 110 dB SPL peak, <1% up to 116 dB SPL peak |
Dynamic range | Typ. 97 dB |
Max. SPL, peak before clipping | 168 dB |
Output impedance | MatchesHMA5000 input |
Cable drive capability | From microphones to HMA5000: Up to 20 m (66 ft), from HMA5000: Up to 300 m (984 ft) |
Power supply | 130 V via HMA5000 |
Connector | 4-pin modified XLR-M (High Voltage) |
Weight | 165 g (5.82 oz) |
Capsule diameter | 19 mm (0.75) |
Length | 175 mm (6.89 in) |